OBDHut

OBDHut

P0941

Professional

Hydraulic Oil Temperature Sensor Circuit Intermittent

What Does P0941 Mean?

DTC P0941 indicates the hydraulic oil temperature sensor circuit is exhibiting intermittent signal dropouts, spikes, or erratic fluctuations that the TCM cannot reconcile with normal thermal behavior. The temperature reading may jump between extreme values or briefly disappear, indicating a marginal electrical connection rather than a hard circuit failure. These intermittent faults often worsen over time as connections degrade further.

Common Causes

35%

Loose or corroded terminals in the sensor connector

25%

Wiring harness with intermittent break (cracked conductor under insulation)

20%

Temperature sensor developing internal intermittent failure

10%

TCM connector with poor pin tension on the temperature sensor input

10%

Vibration-induced contact issues due to improper harness routing or missing clips

Diagnostic Steps

1

Step 1: Monitor the hydraulic oil temperature PID on a scan tool while wiggling the sensor connector and harness at multiple points. Look for sudden value changes or signal dropouts.

2

Step 2: Inspect the sensor connector terminals for corrosion, green oxidation, or evidence of moisture. Clean with electrical contact cleaner and verify terminal tension.

3

Step 3: Check the wiring harness for proper routing and secure mounting clips. Inspect for chafing where the harness contacts body panels, brackets, or other components.

4

Step 4: Perform a road test while monitoring the temperature PID. Note if the intermittent occurs during specific conditions such as bumps, acceleration, or temperature changes.

5

Step 5: If the intermittent source is not found through wiggle testing, replace the sensor as a precaution. Apply dielectric grease to the connector, clear codes, and verify stable readings over multiple drive cycles.

Estimated Repair Cost

$120 - $500

Parts + labor, varies by vehicle and location

Frequently Asked Questions

What does P0941 mean?

DTC P0941 indicates the hydraulic oil temperature sensor circuit is exhibiting intermittent signal dropouts, spikes, or erratic fluctuations that the TCM cannot reconcile with normal thermal behavior. The temperature reading may jump between extreme values or briefly disappear, indicating a marginal...

What causes P0941?

The most common cause of P0941 (Hydraulic Oil Temperature Sensor Circuit Intermittent) is: Loose or corroded terminals in the sensor connector

How much does it cost to fix P0941?

Typical repair costs for P0941 range from $120 to $500, depending on the vehicle, location, and whether you do it yourself or go to a shop.

Is it safe to drive with P0941?

Intermittent temperature sensor signals may cause occasional shift quality variations or momentary protective mode activation. While not typically an immediate safety hazard, the unpredictable nature warrants diagnosis to prevent progression to a hard failure during critical driving situations.

How do I diagnose P0941?

Start by connecting an OBD2 scanner to read the code and any freeze frame data. Then follow the diagnostic steps specific to P0941 to identify the root cause.

OBDHut Mobile App

Scan codes directly from your car with the OBDHut app.

Coming Soon

Quick Info

Category

Powertrain

System

Transmission / Clutch Hydraulic System

Difficulty

Professional

Type

Generic (SAE)

Recommended Tools

OBD2 Scanner

A quality scan tool helps you read codes, view live data, and clear faults.