OBDHut

OBDHut

P0B92

Critical
Professional

Hybrid Battery Voltage Sense "R" Circuit Low

What Does P0B92 Mean?

The battery management system has detected that the voltage reading from hybrid battery sense circuit "R" is below the minimum expected threshold. This indicates a potential deep discharge condition, a shorted cell, or a wiring fault pulling the voltage sense line low.

Safety Warning

A genuinely low cell voltage can lead to cell reversal and thermal runaway. Do not drive until diagnosed. Tow to a qualified hybrid service facility if a cell is confirmed failed.

Common Causes

40%

Shorted or deeply discharged battery cell within module "R"

HV Battery Module
Battery Cell

25%

Voltage sense wire shorted to ground

Voltage Sense Wire
Wiring Harness

20%

Corroded or high-resistance connection causing voltage drop in the sense circuit

Battery Module Connector
Sense Harness Connector

15%

Battery management controller input fault reading low

Battery Management System Module

Diagnostic Steps

1

Step 1: Read the voltage value for cell group "R" via the scan tool to confirm it is below the minimum threshold.

2

Step 2: With the HV system de-energized, directly measure module "R" voltage at its terminals with a DVOM to verify the actual cell voltage.

3

Step 3: If the direct measurement is normal, check the sense wire for shorts to ground.

4

Step 4: If cell voltage is genuinely low, perform a cell balance test and monitor for excessive self-discharge over 24 hours.

5

Step 5: Inspect the battery module for physical damage, leakage, or swelling.

Estimated Repair Cost

$300 - $5,000

Parts + labor, varies by vehicle and location

Frequently Asked Questions

What does P0B92 mean?

The battery management system has detected that the voltage reading from hybrid battery sense circuit "R" is below the minimum expected threshold. This indicates a potential deep discharge condition, a shorted cell, or a wiring fault pulling the voltage sense line low.

What causes P0B92?

The most common cause of P0B92 (Hybrid Battery Voltage Sense "R" Circuit Low) is: Shorted or deeply discharged battery cell within module "R"

How much does it cost to fix P0B92?

Typical repair costs for P0B92 range from $300 to $5,000, depending on the vehicle, location, and whether you do it yourself or go to a shop.

Is it safe to drive with P0B92?

A genuinely low cell voltage can lead to cell reversal and thermal runaway. Do not drive until diagnosed. Tow to a qualified hybrid service facility if a cell is confirmed failed.

How do I diagnose P0B92?

Start by connecting an OBD2 scanner to read the code and any freeze frame data. Then follow the diagnostic steps specific to P0B92 to identify the root cause.

OBDHut Mobile App

Scan codes directly from your car with the OBDHut app.

Coming Soon

Quick Info

Category

Powertrain

System

Hybrid Battery Pack / High-Voltage System

Difficulty

Professional

Type

Generic (SAE)

Recommended Tools

OBD2 Scanner

A quality scan tool helps you read codes, view live data, and clear faults.